Abstract
A new method called constant heat flux method was talked about the calculation of the heat transfer coefficient, h. The way of calculating h for the transient experiment was from step-change solution by giving a constant heat flux suddenly. If the time at which the changes colour of thermochromic liquid crystal(TLC) is known, then h can be found from the solution of so-called semi-infinite plate problem. Uncertainties of h calculated using the so-called two point method were discussed later. On the basis of this discussion it were found out how the accurate h could be got. The procedure of calculating h using constant heat flux method were listed and the free plant experiment are used to prove the method's accuracy.
| Original language | English |
|---|---|
| Pages (from-to) | 883-886 |
| Number of pages | 4 |
| Journal | Beijing Hangkong Hangtian Daxue Xuebao/Journal of Beijing University of Aeronautics and Astronautics |
| Volume | 36 |
| Issue number | 8 |
| State | Published - Aug 2010 |
Keywords
- Heat flux method
- Heat transfer coefficient
- Thermal liquid crystal
- Uncertainties analysis
Fingerprint
Dive into the research topics of 'Transient measurement of heat transfer coefficient'. Together they form a unique fingerprint.Cite this