Abstract
Adiabatic effectiveness (η) is the most important parameter for evaluating film cooling capacity. For turbine blades, it is usually based on the scaling criteria to achieve the mapping of effectiveness from low temperature conditions in the laboratory to real application scenarios. However, with the increase of gas temperature and humidity, the thermal radiation effect is obvious, resulting in the inapplicability of the traditional scaling criteria. In this study, a radiation correction formula was proposed to modify the scaling criteria. Firstly, based on the wide band K-distribution (WBK) model, the absorption coefficients of typical aviation kerosene gas products were calculated. Secondly, the dataset was constructed based on computational fluid dynamics (CFD) assisted design, and Python codes were introduced to automate the post-processing of coefficients. Thirdly, radiation related dimensionless parameters (εw, Tbi, TR, mCO2, mH2O, mO2, mN2) were selected as independent variables. Finally, an explicit function between based on a nonlinear fitting algorithm was obtained. The correlation formula of the scaling criteria proposed was compatible with reasonable flow parameters and model parameters. Compared with the traditional approach, which must be tested at high temperature to fully consider the effects of radiation, the formula proposed in this study is energy-saving and innovative.
| Original language | English |
|---|---|
| Article number | 128965 |
| Journal | Energy |
| Volume | 282 |
| DOIs | |
| State | Published - 1 Nov 2023 |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 7 Affordable and Clean Energy
Keywords
- Band model
- Film cooling
- Guide vane
- Scaling criteria
Fingerprint
Dive into the research topics of 'Thermal radiation correction formula of the scaling criteria for film cooling of turbine blades'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver