Skip to main navigation Skip to search Skip to main content

Test method for FOG loop eigenfrequency

  • Beihang University

Research output: Contribution to journalArticlepeer-review

Abstract

Based on the principle of square wave modulation and demodulation in digital closed-loop FOG, the reasons that results in modulation dead area by using the symmetry square wave were presented and its influence on the measurement accuracy was analyzed. The approach was presented to solve the problem of FOG loop eigenfrequency measuring based on asymmetric square wave modulation of arbitrary duty cycle, and the relationship between the arbitrary duty cycle and the ineffective -modulation area was found.The optimal range of duty cycle of the modulation square was given when testing the loop eigenfrequency.Theory and experiment prove the influence of the duty cycle on measurement accuracy of the loop eigenfrequency.Compared with the symmetry square wave, the method of asymmetry square wave improves measurement accuracy, and reduces the cost of the system hardware.

Original languageEnglish
Pages (from-to)318-321
Number of pages4
JournalInfrared and Laser Engineering
Volume38
Issue number2
StatePublished - 25 Apr 2009

Keywords

  • Arbitrary duty cycle
  • FOG
  • Ineffective-modulation area
  • Loop eigenfrequency
  • Modulation dead area

Fingerprint

Dive into the research topics of 'Test method for FOG loop eigenfrequency'. Together they form a unique fingerprint.

Cite this