Temperature compensation methods of λ/4 wave plate for fiber optic current sensor

  • Beihang University

Research output: Contribution to journal › Article › peer-review

Abstract

Phasic difference temperature error of quarter wave plate is one of the primary errors of fiber optic current transducer (FOCT). Polarization transform procedure of polarized light at quarter wave plate is analyzed. The influence principle of phase difference temperature stability to FOCT scale factor is disclosed. Afterwards, temperature error model of the plate is deduced. By introducing another A/D and performing unequal duty ratio square wave modulation, DC component and kurtosis information of the interference output are distilled respectively. Thus, a temperature error compensation scheme is designed with these two parameters. The experimental results show that FOCT scale factor error is decreased from ±0.75% to ±0.25% at -40-60°C by employing the compensation process.

Original languageEnglish
Pages (from-to)55-59
Number of pages5
JournalDiangong Jishu Xuebao/Transactions of China Electrotechnical Society
Volume23
Issue number12
StatePublished - Dec 2008

Keywords

  • FOCT
  • Quarter wave plate
  • Temperature error compensation
  • Unequal duty ratio

Fingerprint

Dive into the research topics of 'Temperature compensation methods of λ/4 wave plate for fiber optic current sensor'. Together they form a unique fingerprint.