Skip to main navigation Skip to search Skip to main content

Study on Dual-Frequency Imaging of Capacitively Coupled Electrical Impedance Tomography: Frequency Optimization

  • Yandan Jiang
  • , Junchao Huang
  • , Haifeng Ji
  • , Baoliang Wang*
  • , Zhiyao Huang
  • , Manuchehr Soleimani
  • *Corresponding author for this work
  • Zhejiang University
  • The University of Bath

Research output: Contribution to journal › Article › peer-review

Abstract

In this work, a new dual-frequency imaging framework of capacitively coupled electrical impedance tomography (CCEIT) is presented. Unlike conventional single-frequency imaging and recently emerged multifrequency imaging, the dual-frequency imaging adopts two different working frequencies to obtain the real part and the imaginary part of the impedance, respectively. With the real part image and the imaginary part image reconstructed at the two frequencies, the framework further introduces image fusion to obtain the fused image. To achieve the optimal selection of the two frequencies, data collection in a wide frequency range is carried out with a 12-electrode CCEIT sensor, an impedance analyzer, and a computer to obtain the real part and the imaginary part measurements. The multifrequency data are then analyzed in depth, and other two aspects, including the sensitivity distribution and the imaging quality at different frequencies, are also investigated. Research results show that a low working frequency is recommended for the real part, while a relatively high working frequency is recommended for the imaginary part. Within the investigated frequency range of 200 kHz-20 MHz, the working frequencies for the real part and the imaginary part are optimized under the investigated distribution setups. Results of verification experiment show that the proposed framework is effective. Compared with single-frequency CCEIT, dual-frequency CCEIT with the two optimized frequencies has much better imaging performance.

Original languageEnglish
Article number4505718
JournalIEEE Transactions on Instrumentation and Measurement
Volume71
DOIs
StatePublished - 2022
Externally publishedYes

Keywords

  • Capacitively coupled electrical impedance tomography (CCEIT)
  • dual-frequency imaging
  • electrical impedance tomography (EIT)
  • multifrequency measurement acquisition
  • working frequency

Fingerprint

Dive into the research topics of 'Study on Dual-Frequency Imaging of Capacitively Coupled Electrical Impedance Tomography: Frequency Optimization'. Together they form a unique fingerprint.

Cite this