Skip to main navigation Skip to search Skip to main content

Study of centrifugal blood pump non-physiological shear stress induced platelet hemostatic dysfunction

  • School of Biological Science and Medical Engineering
  • Beihang University
  • Department of Cardiopulmonary Bypass
  • Chinese Academy of Medical Sciences

Research output: Contribution to journal › Article › peer-review

Abstract

Objective: To clarify how centrifugal blood pump-induced non-physiological shear stress affects platelet adhesion and aggregation, explaining the coexistence of thrombosis and bleeding during centrifugal pump support. Methods: Blood samples collected before and after centrifugal pump operation were used. Platelet adhesion, aggregation, and binding forces were evaluated using collagen and fibrinogen coated microfluidic chips and micropost arrays. Platelet receptor expression, vWF function, and pro-aggregatory factors were further investigated. Results: After centrifugal pump operation, platelet adhesion to collagen decreased, especially under higher perfusion shear rates. The platelet and collagen binding force decreased from 33.04 nN to 8.73 nN, indicating impaired adhesive stability. This was associated with reduced platelet GPVI and GPIbα receptor expression, decreased vWF activity, and weakened platelet-vWF binding, suggesting inhibition of both GPVI mediated and vWF/GPIbα mediated adhesion. In contrast, platelet binding to fibrinogen increased, especially under higher perfusion shear rates. The platelet and fibrinogen binding force increased from 12.85 nN to 42.29 nN, indicating enhanced aggregation stability. This was accompanied by increased platelet GPIIb/IIIa receptor activation and elevated pro-aggregatory factors. However, prolonged centrifugal pump operation reduced platelet responsiveness to secondary stimulation and decreased GPIIb/GPIIIa subunit availability, suggesting that sustained shear exposure limits further platelet activation and aggregation. Conclusion: Centrifugal blood pump induced non-physiological shear stress impairs collagen mediated initial adhesion while enhancing fibrinogen mediated aggregation. Sustained shear exposure weakens platelet secondary responsiveness and limits further enhancement of aggregation hemostasis. These findings reveal a potential mechanism for the coexistence of thrombosis and bleeding and provide a microfluidic method for hemocompatibility assessment.

Original languageEnglish
Article number109821
JournalThrombosis Research
Volume265
DOIs
StatePublished - Sep 2026

Keywords

  • Adhesive and aggregation
  • Binding force
  • Centrifugal blood pump
  • Platelet
  • Shear stress

Fingerprint

Dive into the research topics of 'Study of centrifugal blood pump non-physiological shear stress induced platelet hemostatic dysfunction'. Together they form a unique fingerprint.

Cite this