Abstract

To guarantee high measurement accuracy, star sensors must be precisely calibrated prior to use. Existing star sensor calibration methods, such as the imaging model method with intrinsic parameters and the polynomial fitting method, exhibit disadvantages. Inspired by classic camera calibration theory, a novel star sensor calibration method based on integrated modelling with intrinsic and extrinsic parameters is proposed in this paper to overcome the inherent disadvantages. A complete, integrated imaging model for star sensors is established by using all intrinsic and extrinsic parameters. Calibration points' data are then acquired by using a two-axis rotary table and a star simulator. Finally, a two-step procedure is applied to calculate the parameters. Experimental results show that the proposed calibration method is capable of obtaining all the intrinsic and extrinsic parameters of the star sensor with high accuracy and efficiency and guarantees highly accurate attitude measurements.

Original languageEnglish
Pages (from-to)117-125
Number of pages9
JournalMeasurement: Journal of the International Measurement Confederation
Volume55
DOIs
StatePublished - Sep 2014

Keywords

  • Attitude measurement
  • Calibration
  • Star sensor

Fingerprint

Dive into the research topics of 'Star sensor calibration based on integrated modelling with intrinsic and extrinsic parameters'. Together they form a unique fingerprint.