Abstract

An experimental study of the spray characteristics of side unlike impinging platelet injector was conducted using a Particle Dynamics Analyzer (PDA). The droplet velocities, diameter and flux density of the spray were measured at three axial locations. The atomization process and special spray feature have been analyzed. The results show that the atomization process is different from that of common impinging injector. The mixing ratio γm and geometric parameters have important effect on the atomization and spray distribution. For a certain γm and passage area ratio γa, there is an optimum nozzle geometry to attain good atomization and spray pattern. On the other hand, both higher γa and γm can improve atomization performance within an appropriate nozzle width. The atomization performance and spray pattern can be controlled by selecting appropriate and geometric parameters.

Original languageEnglish
Pages (from-to)202-207
Number of pages6
JournalHangkong Dongli Xuebao/Journal of Aerospace Power
Volume20
Issue number2
StatePublished - Apr 2005

Keywords

  • Aerospace propulsion system
  • Atomization
  • Platelet injector
  • Spray pattern
  • Unlike impinging