Soft sensing method of ls-svm using temperature time series for gas flow measurements

Research output: Contribution to journalArticlepeer-review

Abstract

This paper proposes a soft sensing method of least squares support vector machine (LS-SVM) using temperature time series for gas flow measurements. A heater unit has been installed on the external wall of a pipeline to generate heat pulses. Dynamic temperature signals have been collected upstream of the heater unit. The temperature time series are the main secondary variables of soft sensing technique for estimating the flow rate. A LS-SVM model is proposed to construct a non-linear relation between the flow rate and temperature time series. To select its inputs, parameters of the measurement system are divided into three categories: blind, invalid and secondary variables. Then the kernel function parameters are optimized to improve estimation accuracy. The experiments have been conducted both in the single-pulse and multiple-pulse heating modes. The results show that estimations are acceptable.

Original languageEnglish
Pages (from-to)383-392
Number of pages10
JournalMetrology and Measurement Systems
Volume22
Issue number3
DOIs
StatePublished - 1 Sep 2015

Keywords

  • Gas flow
  • Soft sensor
  • Support vector machine
  • Temperature time series

Fingerprint

Dive into the research topics of 'Soft sensing method of ls-svm using temperature time series for gas flow measurements'. Together they form a unique fingerprint.