Skip to main navigation Skip to search Skip to main content

Single-beam atomic magnetometry with sub-nanotesla heading error based on hyperfine alignment resonances

  • Junlin Chen
  • , Liwei Jiang*
  • , Jiaqi Yang
  • , Changhao Zhang
  • , Zhihao Peng
  • , Shihao Bei
  • , Jiali Liu
  • *Corresponding author for this work
  • Large-scale Scientific Facility and Centre for Zero Magnetic Field Science
  • Beihang University
  • National Institute of Extremely-Weak Magnetic Field Infrastructure

Research output: Contribution to journal › Article › peer-review

Abstract

Heading error is a major limitation for resonance-based atomic magnetometers operating in the geomagnetic-field range, where the magnetic-field direction often changes with respect to the sensor. Here, we investigate the physical origin of heading error in a single-beam amplitude-modulated nonlinear magneto-optical rotation magnetometer based on the hyperfine alignment resonances of the (Formula presented) (Formula presented) Rb D1 line in a buffer-gas vapor cell. Unlike orientation-based magnetometers, where nonlinear Zeeman effects usually constitute a major source of heading error, the (Formula presented) (Formula presented) alignment resonance spectrum maintains a stable center frequency under different magnetic-field orientations when the individual resonance components are unresolved. In practical single-beam measurements, the observed heading error is associated with an orientation-dependent residual spectral background, which breaks the apparent symmetry of the alignment-resonance profile and biases the extracted center frequency. To suppress this background-induced bias, we propose a multi-point frequency extraction method that retrieves the resonance center from distorted single-beam spectra. In unshielded geomagnetic-field measurements, the equal-weight pooled peak-to-peak heading-error estimate for the (Formula presented) (Formula presented) manifold is reduced to 0.32 nT, with a one-sided 95% upper coverage limit of 0.90 nT. Separately, an estimated photon-shot-noise-limited sensitivity of about (Formula presented) (Formula presented) is obtained. These results provide a compact route to low-heading-error and high-sensitivity atomic magnetometry for practical geomagnetic-field quantum sensing.

Original languageEnglish
Article number045051
JournalQuantum Science and Technology
Volume11
Issue number4
DOIs
StatePublished - Dec 2026

Keywords

  • atomic magnetometers
  • heading error
  • light shift
  • nonlinear magneto-optical rotation
  • nonlinear Zeeman effect

Fingerprint

Dive into the research topics of 'Single-beam atomic magnetometry with sub-nanotesla heading error based on hyperfine alignment resonances'. Together they form a unique fingerprint.

Cite this