Skip to main navigation Skip to search Skip to main content

Shear-induced platelet receptor shedding by non-physiological high shear stress with short exposure time: Glycoprotein Ibα and glycoprotein VI

  • Zengsheng Chen
  • , Nandan K. Mondal
  • , Jun Ding
  • , Jingya Gao
  • , Bartley P. Griffith
  • , Zhongjun J. Wu*
  • *Corresponding author for this work
  • University of Maryland, Baltimore
  • University of Maryland, Baltimore County
  • Sienna College

Research output: Contribution to journalArticlepeer-review

Abstract

Introduction The structural integrity of platelet receptors is essential for platelets to function normally in hemostasis and thrombosis in response to physiological and pathological stimuli. The aim of this study was to examine the shedding of two key platelet receptors, glycoprotein (GP) Ibα and GPVI, after exposed to the non-physiological high shear stress environment which commonly exists in blood contacting medical devices and stenotic blood vessels. Materials and Methods In this in vitro experiment, we exposed healthy donor blood in our specially designed blood shearing device to three high shear stress levels (150, 225, 300 Pa) in combination with two short exposure time conditions (0.05 and 0.5 sec.). The expression and shedding of platelet GPIbα and GPVI receptors in the sheared blood samples were characterized using flow cytometry. The ability of platelet aggregation induced by ristocetin and collagen related to GPIbα and GPVI in the sheared blood samples, respectively, was evaluated by aggregometry. Results and Conclusions Compared to the normal blood, the surface expression of platelet GPIbα and GPVI in the sheared blood significantly decreased with increasing shear stress and exposure time. Moreover, the platelet aggregation induced by ristocetin and collagen reduced remarkably in a similar fashion. In summary non-physiological high shear stresses with short exposure time can induce shedding of platelet GPIbα and GPVI receptors, which may lead platelet dysfunction and influence the coagulation system. This study may provide a mechanistic insight into the platelet dysfunction and associated bleeding complication in patients supported by certain blood contacting medical devices.

Original languageEnglish
Pages (from-to)692-698
Number of pages7
JournalThrombosis Research
Volume135
Issue number4
DOIs
StatePublished - 1 Apr 2015
Externally publishedYes

Keywords

  • Blood contacting medical devices
  • Platelet aggregation
  • Platelet dysfunction
  • Platelet receptor shedding
  • Shear stress

Fingerprint

Dive into the research topics of 'Shear-induced platelet receptor shedding by non-physiological high shear stress with short exposure time: Glycoprotein Ibα and glycoprotein VI'. Together they form a unique fingerprint.

Cite this