Skip to main navigation Skip to search Skip to main content

Scale-up of an electrical capacitance tomography sensor for imaging pharmaceutical fluidized beds and validation by computational fluid dynamics

  • Haigang Wang*
  • , Wuqiang Yang
  • *Corresponding author for this work
  • University of Manchester
  • Chinese Academy of Sciences

Research output: Contribution to journal › Article › peer-review

Abstract

The aim of this research is to apply electrical capacitance tomography (ECT) in pharmaceutical fluidized beds and scale up the application of ECT from a lab-scale fluidized bed to a production-scale fluidized bed. The objective is to optimize the design of the production-scale fluidized bed and to improve the operation efficiency of the fluidization processes. This is the first time that ECT has been scaled up to a production-scale fluidized bed of 1.0 m diameter and batch process capacity of 100 kg in a real industrial environment. With a large-scale fluidized bed in a real industrial environment, some key issues on the ECT sensor design must be addressed. To validate ECT measurement results, a two-phase flow model has been used to simulate the process in a lab-scale and pilot-scale fluidized bed. The key process parameters include solid concentration, average concentration profiles, the frequency spectrum of signal fluctuation obtained by the fast Fourier transfer (FFT) and multi-level wavelet decomposition in the time domain. The results show different hydrodynamic behaviour of fluidized beds of different scales. The time-averaged parameters from ECT and computational fluid dynamics are compared. Future work on the ECT sensor design for large-scale fluidized beds are given in the end of the paper.

Original languageEnglish
Article number104015
JournalMeasurement Science and Technology
Volume22
Issue number10
DOIs
StatePublished - Oct 2011
Externally publishedYes

Keywords

  • CFD
  • ECT
  • pharmaceutical fluidized bed
  • scale-up

Fingerprint