Skip to main navigation Skip to search Skip to main content

Research on fault-tolerant control for magnetic bearings biased by permanent magnetic

  • Beihang University

Research output: Contribution to journalArticlepeer-review

Abstract

The control system of magnetic bearing has a complex structure. Even the damage of a single control channel will lead to the failure of the whole magnetic bearing system. The reliability requirements limit magnetic bearings from being used in critical applications. To improve the reliability, a fault-tolerant current distribution scheme is presented for a magnetic bearing biased by permanent magnet. In this scheme, the one-dimensional magnetic circuit is used to analyze the force nearby the equilibrium point, and the current distribution matrices are obtained through analyzing the relationship between the normal control-current and the fault control-current. The scheme is effective and easy to implement in engineering. The experimental results indicate that the fault-tolerant scheme can realize static suspension and speed-raising of magnetically suspended flywheel on condition that the coil (power amplifier) is damaged, thus improving the reliability of the magnetic bearing system.

Original languageEnglish
Pages (from-to)34-40
Number of pages7
JournalJixie Gongcheng Xuebao/Journal of Mechanical Engineering
Volume46
Issue number20
DOIs
StatePublished - 20 Oct 2010

Keywords

  • Fault-tolerant control
  • Homopolar
  • Magnetic bearing
  • Reliability

Fingerprint

Dive into the research topics of 'Research on fault-tolerant control for magnetic bearings biased by permanent magnetic'. Together they form a unique fingerprint.