TY - GEN
T1 - Research on fatigue properties of micron scale copper bonding wires
AU - Zhao, Zihua
AU - Qi, Fengcai
AU - Zhao, Shuang
AU - Lei, Ming
N1 - Publisher Copyright:
© 2017 Trans Tech Publications, Switzerland.
PY - 2017
Y1 - 2017
N2 - Copper bonding wires are frequently used to connect to Micro-Electro-Mechanical System (MEMS) devices. Mechanical properties of copper wire are crucial to the reliability of MEMS system. The paper reported a symmetrical bending fatigue test on micron scale copper bonding wires. The test is based on the phenomenon that a micro-cantilever can be set into self-excited vibration between two electrodes under DC voltage. The results demonstrate that the yield strength, ultimate tensile strength and Young's modulus of copper wires with diameter of 20 μm are higher than those with a diameter of 30 μm and 40 μm, which significantly performs size effect. In fatigue test, the number of cycles to failure is 104~107. Under the same stress condition, fatigue strength (N=106) of copper wires (d=20 μm, 30 μm, 40 μm) is 140 MPa, 97 MPa, 70 MPa respectively. The tensile fracture surface is the chisel-shaped peak, and the surface of the fracture appears many spaced strip drawing traces. The fatigue fracture surface is flat. Two cracks almost simultaneously originate from the surface, and the final rupture region is just like a narrow sheet.
AB - Copper bonding wires are frequently used to connect to Micro-Electro-Mechanical System (MEMS) devices. Mechanical properties of copper wire are crucial to the reliability of MEMS system. The paper reported a symmetrical bending fatigue test on micron scale copper bonding wires. The test is based on the phenomenon that a micro-cantilever can be set into self-excited vibration between two electrodes under DC voltage. The results demonstrate that the yield strength, ultimate tensile strength and Young's modulus of copper wires with diameter of 20 μm are higher than those with a diameter of 30 μm and 40 μm, which significantly performs size effect. In fatigue test, the number of cycles to failure is 104~107. Under the same stress condition, fatigue strength (N=106) of copper wires (d=20 μm, 30 μm, 40 μm) is 140 MPa, 97 MPa, 70 MPa respectively. The tensile fracture surface is the chisel-shaped peak, and the surface of the fracture appears many spaced strip drawing traces. The fatigue fracture surface is flat. Two cracks almost simultaneously originate from the surface, and the final rupture region is just like a narrow sheet.
KW - Fatigue
KW - Micron copper wire
KW - Size effect
UR - https://www.scopus.com/pages/publications/85018994418
U2 - 10.4028/www.scientific.net/KEM.734.176
DO - 10.4028/www.scientific.net/KEM.734.176
M3 - 会议稿件
AN - SCOPUS:85018994418
SN - 9783035711066
T3 - Key Engineering Materials
SP - 176
EP - 184
BT - Small Sample Test Technique
A2 - Guan, Kaishu
A2 - Matocha, Karel
A2 - Xu, Tong
PB - Trans Tech Publications Ltd
T2 - 4th International Conference on Small Sample Test Technique, SSTT 2016
Y2 - 12 October 2016 through 14 October 2016
ER -