Skip to main navigation Skip to search Skip to main content

Research and implementation of amplitude ratio calculating system for Coriolis Mass Flowmeter

  • Chun Hu*
  • , Dezhi Zheng
  • , Shangchun Fan
  • , Jingjie Gong
  • *Corresponding author for this work
  • Beihang University

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

Abstract

Coriolis mass flow sensor tends to be straight tube and micro bending tube with higher noise rejecting and less pressure loss, which results in the increase of the operating frequency, the difficulty in detecting phase difference and the calculation accuracy. Based on the current method of amplitude ratio calculation, the paper analyzes how the Coriolis Mass Flowmeter (CMF) closed-loop control system affects the amplitude ratio calculation, and presents a theoretical method with the amplitude of the driving signal participating in calculation. To achieve high-precision measurement of the amplitude, a comparative analysis by Matlab of curve fitting, correlation detection, windowed FFT detection in the case of signal amplitude fluctuation, frequency fluctuation and signal to noise variation, indicates that curve fitting is the suitable method to measure the signal amplitude. In the implementation of the system, a three-channel parallel data acquisition system is built to detect the CMF output signal. In order to eliminate the error brought by the differences between the channels, an automatic channel switching system is proposed to acquire the relative difference of each channel, then calibrate and calculate the flow signal of each channel. The preliminary experimental results demonstrate that the amplitude ratio calculating is available in calculating the mass flow rate of the CMF, with nonlinear error of 0.5% and repeatability of 0.6%.

Original languageEnglish
Title of host publication2012 the 8th IEEE International Symposium on Instrumentation and Control Technology, ISICT 2012 - Proceedings
Pages147-152
Number of pages6
DOIs
StatePublished - 2012
Event8th IEEE International Symposium on Instrumentation and Control Technology, ISICT 2012 - London, United Kingdom
Duration: 11 Jul 201213 Jul 2012

Publication series

Name2012 the 8th IEEE International Symposium on Instrumentation and Control Technology, ISICT 2012 - Proceedings

Conference

Conference8th IEEE International Symposium on Instrumentation and Control Technology, ISICT 2012
Country/TerritoryUnited Kingdom
CityLondon
Period11/07/1213/07/12

Keywords

  • Coriolis mass flowmeter
  • amplitude ratio calculation
  • correlation detection
  • curve fitting
  • signal amplitude measurement
  • windowed FFT detection

Fingerprint

Dive into the research topics of 'Research and implementation of amplitude ratio calculating system for Coriolis Mass Flowmeter'. Together they form a unique fingerprint.

Cite this