Skip to main navigation Skip to search Skip to main content

Quantification of stenosis in coronary artery via CTA using fuzzy distance transform

  • Yan Xu*
  • , Punam K. Saha
  • , Guangshu Hu
  • , Guoyuan Liang
  • , Yan Yang
  • , Jinzhao Geng
  • *Corresponding author for this work
  • University of Iowa
  • Tsinghua University
  • Georgia Institute of Technology

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

Abstract

Quantification of stenosis in coronary artery is useful for diagnosis of several coronary heart diseases. Computed tomographic angiography (CTA) being noninvasive, economical and informative, has become a common modality for monitoring disease status and treatment effects. Here, we present a new method for detecting and quantifying coronary arterial stenosis via CTA using fuzzy distance transform (FDT) approach. FDT computes local depth at each image point in the presence of partial voluming. Coronary arterial stenoses are detected and their severities are quantified by analyzing FDT values along the medial axis of an artery obtained by skeletonization. Also, we have developed a new skeletal pruning algorithm toward improving quality of medial axes and therefore, enhancing the accuracy of stenosis detection and quantification. The method is completed using the following steps - (1) fuzzy segmentation of coronary artery via CTA, (2) FDT computation of coronary arteries, (3) medial axis computation, (4) estimation of local diameter along arteries and (5) stenosis detection and quantification of arterial blockage. Performance of the method has been quantitatively evaluated on a realistic coronary artery phantom dataset with randomly simulated stenoses and the results are compared with a classical binary algorithm. The method has also been applied on a clinical CTA dataset from thirteen patients with 59 stenoses and the results are compared with an expert's quantitative assessment of stenoses. Results of the phantom experiment indicate that the new method is significantly more accurate as compared to the conventional binary method. Also, the results of the clinical study indicate that the computerized method is highly in agreement with the expert's assessments.

Original languageEnglish
Title of host publicationMedical Imaging 2009
Subtitle of host publicationBiomedical Applications in Molecular, Structural, and Functional Imaging
DOIs
StatePublished - 2009
Externally publishedYes
EventMedical Imaging 2009: Biomedical Applications in Molecular, Structural, and Functional Imaging - Lake Buena Vista, FL, United States
Duration: 8 Feb 200910 Feb 2009

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume7262
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2009: Biomedical Applications in Molecular, Structural, and Functional Imaging
Country/TerritoryUnited States
CityLake Buena Vista, FL
Period8/02/0910/02/09

Keywords

  • CTA
  • Coronary artery
  • Curve pruning
  • Fuzzy distance transform
  • Skeletonization
  • Stenosis
  • Voxel-based morphometry.

Fingerprint

Dive into the research topics of 'Quantification of stenosis in coronary artery via CTA using fuzzy distance transform'. Together they form a unique fingerprint.

Cite this