Abstract
In order to assess performance of PM1 size selectors, two measurement system were designed and evaluated. Polydisperse aerosol measurement system generated stable aerosols and the aerosols in the chamber were in good spatial uniformity. The aerosol generated showed a lognormal distribution. Monodisperse aerosol measurement system generated stable aerosols with excellent monodispersion. The performances of five types of PM1 cyclone were evaluated by the two systems. The results from two system were consistent with each other. Cutting diameter (D50) of five types of PM1 cyclone were (1.0±0.1) μm. Geometric standard deviation (σg) of two groups of the cyclone (sharp-cut and Stairmand) were 1.2±0.1 and 1.4±0.1, respectively.
| Translated title of the contribution | Design and application of performance evaluation system for PM1 size selectors |
|---|---|
| Original language | Chinese (Traditional) |
| Pages (from-to) | 1797-1803 |
| Number of pages | 7 |
| Journal | Huanjing Kexue Xuebao / Acta Scientiae Circumstantiae |
| Volume | 38 |
| Issue number | 5 |
| DOIs | |
| State | Published - 6 May 2018 |