Abstract
We explore the impact of pumping beams with different transverse intensity profiles on the performance of the spin-exchange relaxation-free (SERF) atomic magnetometers (AMs). We conduct experiments comparing the traditional Gaussian optically-pumped AM with that utilizing the flat-top optically-pumped (FTOP) method. Our findings reveal that the FTOP-based approach outperforms the conventional method, exhibiting a larger response, a narrower magnetic resonance linewidth, and a superior low-frequency noise performance. Specifically, the use of FTOP method leads to a 16% enhancement in average sensitivity within 1 Hz-30 Hz frequency range. Our research emphasizes the significance of achieving transverse polarization uniformity in AMs, providing insights for future optimization efforts and sensitivity improvements in miniaturized magnetometers.
| Original language | English |
|---|---|
| Article number | 060703 |
| Journal | Chinese Physics B |
| Volume | 33 |
| Issue number | 6 |
| DOIs | |
| State | Published - 1 May 2024 |
Keywords
- atomic magnetometer (AM)
- flat-top light beam
- performance optimization
- spin-exchange relaxation-free (SERF)
Fingerprint
Dive into the research topics of 'Performance optimization of a SERF atomic magnetometer based on flat-top light beam'. Together they form a unique fingerprint.Cite this