Abstract
A parametric dynamic phasor (PDP) model of diode rectifiers has been recently proposed, which uses a computer-aided approach to effectively represent the rectifier dynamics including ac-side harmonics that change with system conditions. This letter extends the PDP methodology to thyristor-controlled rectifier systems where the dc-link voltage is regulated via the thyristor firing control. Steady state and large-signal transient studies demonstrate that the new/extended model is accurate even for prediction of harmonics for various operating modes.
| Original language | English |
|---|---|
| Article number | 8000601 |
| Pages (from-to) | 1626-1629 |
| Number of pages | 4 |
| Journal | IEEE Transactions on Energy Conversion |
| Volume | 32 |
| Issue number | 4 |
| DOIs | |
| State | Published - Dec 2017 |
| Externally published | Yes |
Keywords
- Dynamic phasor
- harmonics
- machine-converter systems
- parametric model
- thyristor-controlled rectifiers
Fingerprint
Dive into the research topics of 'Parametric Dynamic Phasor Modeling of Thyristor-Controlled Rectifier Systems Including Harmonics for Various Operating Modes'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver