Skip to main navigation Skip to search Skip to main content

Novel miniature transendoscopic telerobotic system for endoscopic submucosal dissection (with videos)

  • Xiaoxiao Yang
  • , Huxin Gao
  • , Shichen Fu
  • , Rui Ji
  • , Cheng Hou
  • , Huicong Liu
  • , Nan Luan
  • , Hongliang Ren
  • , Liping Sun
  • , Jialin Yang
  • , Zhifeng Zhou
  • , Xiaoyun Yang
  • , Lining Sun
  • , Yanqing Li
  • , Xiuli Zuo*
  • *Corresponding author for this work
  • Qilu Hospital of Shandong University
  • National University of Singapore
  • Chinese University of Hong Kong
  • Soochow University
  • Shanghai Jiao Tong University
  • Shanghai University of Medicine and Health Sciences
  • Ltd
  • Huaco Healthcare Technologies Co Ltd

Research output: Contribution to journalArticlepeer-review

Abstract

Background and Aims: The lack of tissue traction and instrument dexterity to allow for adequate visualization and effective dissection were the main issues in performing endoscopic submucosal dissection (ESD). Robot-assisted systems may provide advantages. In this study we developed a novel transendoscopic telerobotic system and evaluated its performance in ESD. Methods: A miniature dual-arm robotic endoscopic assistant for minimally invasive surgery (DREAMS) was developed. The DREAMS system contained the current smallest robotic ESD instruments and was compatible with the commercially available dual-channel endoscope. After the system was established, a prospective randomized controlled study was conducted to validate the performance of the DREAMS-assisted ESD in terms of efficacy, safety, and workload by comparing it with the conventional technique. Results: Two robotic instruments can achieve safe collaboration and provide sufficient visualization and efficient dissection during ESD. Forty ESDs in the stomach and esophagus of 8 pigs were completed by DREAMS-assisted ESD or conventional ESD. Submucosal dissection time was comparable between the 2 techniques, but DREAMS-assisted ESD demonstrated a significantly lower muscular injury rate (15% vs 50%, P = .018) and workload scores (22.30 vs 32.45, P < .001). In the subgroup analysis of esophageal ESD, DREAMS-assisted ESD showed significantly improved submucosal dissection time (6.45 vs 16.37 minutes, P = .002), muscular injury rate (25% vs 87.5%, P = .041), and workload (21.13 vs 40.63, P = .001). Conclusions: We developed a novel transendoscopic telerobotic system, named DREAMS. The safety profile and technical feasibility of ESD were significantly improved with the assistance of the DREAMS system, especially in the narrower esophageal lumen.

Original languageEnglish
Pages (from-to)155-165.e4
JournalGastrointestinal Endoscopy
Volume99
Issue number2
DOIs
StatePublished - Feb 2024
Externally publishedYes

Fingerprint

Dive into the research topics of 'Novel miniature transendoscopic telerobotic system for endoscopic submucosal dissection (with videos)'. Together they form a unique fingerprint.

Cite this