Herein, porous Co3O4 nanoneedle arrays were synthesized on nickel (Ni) foam (Co3O4 NNs/NF) by one-step hydrothermal method. Some electrochemical methods were used to investigate its nonenzymatic glucose sensing performance in alkaline solution. The results show that the sensitivity of Co3O4 NNs/NF electrode to glucose is 4570 μA mM-1 cm-2. The linear range is 1 μM-0.337 mM, and the detection limit is 0.91 μM (S/N=3). It also displays good selectivity and repeatability for glucose. The good electrochemical sensing performance of Co3O4 NNs/NF based sensor for glucose can be attributed to interconnected porous structure and large specific surface area of Co3O4.
| Original language | English |
|---|---|
| Article number | 6442241 |
| Journal | Journal of Environmental and Public Health |
| Volume | 2022 |
| DOIs | |
| State | Published - 2022 |