Skip to main navigation Skip to search Skip to main content

Multimodal Phase-Space Dynamics Fusion for Robust Ischemia Screening: An Edge-AI Paradigm with SERF Magnetocardiography

  • Keyi Li
  • , Xiangyang Zhou
  • , Yifan Jia
  • , Ruizhe Wang
  • , Yidi Cao
  • , Jiaojiao Pang
  • , Rui Shang
  • , Yadan Zhang
  • , Yangyang Cui*
  • , Dong Xu*
  • , Min Xiang*
  • *Corresponding author for this work
  • Beihang University
  • Hefei National Laboratory
  • Qilu Hospital of Shandong University
  • Hangzhou Institute of National Extremely-weak Magnetic Field Infrastructure

Research output: Contribution to journalArticlepeer-review

Abstract

Background: Myocardial ischemia (MI) is a major cause of morbidity and mortality worldwide and requires timely and reliable detection. Although Spin-Exchange Relaxation-Free (SERF) magnetocardiography (MCG) provides femtotesla-level sensitivity for identifying non-linear cardiac repolarization anomalies, its clinical deployment is currently impeded by the computational bottlenecks inherent to portable edge platforms. Methods: We propose a “Sensor-to-Image” Edge-AI framework that links quantum sensing with computer vision. Single-channel SERF-MCG signals from a large cohort of 2118 subjects (1135 Healthy, 983 Ischemia) were transformed into phase-space images using three distinct encoding modalities: Recurrence Plots (RP), Gramian Angular Summation Fields (GASF), and Markov Transition Fields (MTF). These visual representations were subsequently analyzed by a streamlined MobileNetV3-Small architecture, optimized for low-latency inference. To maximize diagnostic precision, an adaptive weighted fusion mechanism was engineered to combine the chaotic specificity captured by RP with the morphological sensitivity of GASF through a validation-optimized fixed global weighting strategy. Results: In our experiments, the fusion model achieved an Area Under the Curve (AUC) of 0.865, which was higher than the 1D-CNN baseline (AUC 0.857) and the single-modality models. Notably, the fusion strategy significantly elevated sensitivity to 88.3% while maintaining a specificity of 66.5%. Although specificity is moderate, this trade-off prioritizes high sensitivity to minimize false negatives in pre-hospital screening scenarios. The average inference time was 4.7 ms per sample on a standard CPU, suggesting suitability for real-time Point-of-Care (PoC) scenarios under further on-device validation. Conclusions: The results suggest that multi-view phase-space fusion can capture subtle spatio-temporal changes associated with ischemia. The proposed lightweight framework may support the development of portable SERF-MCG systems with embedded AI screening.

Original languageEnglish
Article number228
JournalBiosensors
Volume16
Issue number4
DOIs
StatePublished - Apr 2026

Keywords

  • Edge AI
  • Portable Biosensors
  • SERF magnetocardiography
  • deep learning
  • ischemia screening
  • phase-space reconstruction

Fingerprint

Dive into the research topics of 'Multimodal Phase-Space Dynamics Fusion for Robust Ischemia Screening: An Edge-AI Paradigm with SERF Magnetocardiography'. Together they form a unique fingerprint.

Cite this