TY - GEN
T1 - Miniaturized and Integrated On-Chip Ag/AgCl Micro-electrodes for Chemical Detection
AU - Liang, Jing
AU - Jia, Xiaotao
AU - Hu, Yuanqi
N1 - Publisher Copyright:
© 2024 IEEE.
PY - 2024
Y1 - 2024
N2 - This work proposes a fabrication and optimization process of miniature Ag/AgCl reference electrodes (RE) at a micrometer (μm) scale for the miniaturized chemical sensors, and these electrodes could also be integrated into a single CMOS chip with solid-state sensors, e.g., ISFET. The thin silver films are first grown by magnetron sputtering and chemically chloridized afterward to form the Ag/AgCl microelectrodes. Different chlorination durations and current densities have been applied to investigate the best fabrication recipe. Both scanning electron microscope (SEM) and energy dispersive spectroscopy (EDS) have been used to analyze the physical composition of electrodes under different recipes. The electrical performance of the proposed micro-electrode has been compared with a standard saturated calomel electrode (SCE), and it is observed that the electrode fabricated with an optimized recipe could provide less than 4 mV accuracy within the pH range from 4 to 10 and more than 200 minutes product life even with only 1.95 × 105μm2 area.
AB - This work proposes a fabrication and optimization process of miniature Ag/AgCl reference electrodes (RE) at a micrometer (μm) scale for the miniaturized chemical sensors, and these electrodes could also be integrated into a single CMOS chip with solid-state sensors, e.g., ISFET. The thin silver films are first grown by magnetron sputtering and chemically chloridized afterward to form the Ag/AgCl microelectrodes. Different chlorination durations and current densities have been applied to investigate the best fabrication recipe. Both scanning electron microscope (SEM) and energy dispersive spectroscopy (EDS) have been used to analyze the physical composition of electrodes under different recipes. The electrical performance of the proposed micro-electrode has been compared with a standard saturated calomel electrode (SCE), and it is observed that the electrode fabricated with an optimized recipe could provide less than 4 mV accuracy within the pH range from 4 to 10 and more than 200 minutes product life even with only 1.95 × 105μm2 area.
KW - ISFET
KW - Micro-electrodes
KW - electrode fabrication
KW - miniaturized sensing
KW - single-chip integration
UR - https://www.scopus.com/pages/publications/85198549863
U2 - 10.1109/ISCAS58744.2024.10558327
DO - 10.1109/ISCAS58744.2024.10558327
M3 - 会议稿件
AN - SCOPUS:85198549863
T3 - Proceedings - IEEE International Symposium on Circuits and Systems
BT - ISCAS 2024 - IEEE International Symposium on Circuits and Systems
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2024 IEEE International Symposium on Circuits and Systems, ISCAS 2024
Y2 - 19 May 2024 through 22 May 2024
ER -