Skip to main navigation Skip to search Skip to main content

Microwave microfluidic sensors for analyzing magnetic bead-based bioliquids: from theory to experimental validation

  • Linxiang Shao
  • , Xiue Bao*
  • , Zhaoying Li
  • , Chaoran Xing
  • , Giovanni Crupi
  • , Giovanni Gugliandolo
  • , Mariangela Latino
  • , Liming Si
  • , Houjun Sun
  • , Lianggong Wen
  • *Corresponding author for this work
  • Beijing Institute of Technology
  • Beihang University
  • University of Messina
  • National Research Council of Italy

Research output: Contribution to journalArticlepeer-review

Abstract

Two novel microwave sensors integrated with microfluidic techniques are introduced and experimentally validated, intended for testing magnetic bead solutions. The first is a transmission line sensor that operates over a wide frequency range from 1 GHz to 110 GHz, utilizing an easily integrable coplanar waveguide (CPW) structure. The second sensor is based on resonant principles and operates at approximately 25 GHz, composed of a CPW structure and a spiral-shaped defect ground structure (DGS). By selecting this frequency band, the minimum size of the DGS sensing area is restricted to 296 μm, about 0.025λ0, which greatly reduces the volume of liquid samples needed. The transmission parameters of both sensors are analyzed using air, deionized (DI) water/ethanol solution, and magnetic bead solution as materials under test (MUTs). Micro-nano fabrication and on-chip measurements are conducted to validate the proposed sensors. Experimental results for the transmission line sensor demonstrate that the variation in |S11| can be used as a parameter to detect magnetic beads in solutions across a wide frequency range. For the resonance sensor, the measurements show that an increase in the real part of the complex relative permeability results in a redshift of the resonance frequency, whereas an increase in the imaginary part reduces the quality factor. These effects are consistent with those observed for complex permittivity. However, a notable difference is that an increase in the real part of permeability also causes a slight decrease in |S21|, which aids in signal detection. In addition to the proposed sensors, a terahertz (THz) spectroscopy transmission method is also experimentally employed to investigate the permittivity of different types and concentrations of magnetic bead solutions. Our study offers a new perspective for enhancing detection sensitivity in microwave microfluidic biosensors by co-utilizing permittivity and permeability. This approach shows great promise for applications in cell sorting and precise measurement of bioliquids.

Original languageEnglish
Pages (from-to)15584-15593
Number of pages10
JournalPhysical Chemistry Chemical Physics
Volume27
Issue number29
DOIs
StatePublished - 23 Jul 2025

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Fingerprint

Dive into the research topics of 'Microwave microfluidic sensors for analyzing magnetic bead-based bioliquids: from theory to experimental validation'. Together they form a unique fingerprint.

Cite this