Measurement method and experimental research of the temperature dependence of the phase delay of quarter-wave plates

  • Xiaxiao Wang
  • , Ye Wang*
  • , Chuansheng Li
  • , Yi Qin
  • , Aimin Wang
  • , Zhiqiang Peng
  • *Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

Abstract

The fiber quarter-wave plates are an important part of fiber-optic current transformers (FOCT). In order to decrease the error caused by the quarter-wave plates on the ratio under the varying temperature environments, more accurate relationship between the temperature and the phase delay of fiber quarter-wave plates is required. Based on the intensity method, a measuring way of the temperature dependence of the phase delay of quarter-wave plates is put forward. It is applied to measure fiber quarter-wave plates in real time and continuously. A mathematical model of the test systems is established by using Jones matrix, and the temperature characteristics of the quarter-wave retarder are tested. The experimental results show that: the relationship between the temperature and the phase delay is linear, and the temperature coefficient of inland quarter-wave plates is much larger than that of the abroad ones; in the temperature self compensation technology of ratio error of FOCT, the smaller the temperature coefficient of the phase delay of quarter-wave plates is, the higher the self compensation limit precision is and the wider the original phase retardation is.

Original languageEnglish
Article number1205004
JournalZhongguo Jiguang/Chinese Journal of Lasers
Volume40
Issue number12
DOIs
StatePublished - Dec 2013

Keywords

  • Elliptical core polarization maintaining fiber
  • Fiber optics
  • Fiber-optic current transformer
  • Fiber-optic plate

Fingerprint

Dive into the research topics of 'Measurement method and experimental research of the temperature dependence of the phase delay of quarter-wave plates'. Together they form a unique fingerprint.

Cite this