Abstract
An experimental program was designed to determine whether or not there exists an optimum time for applying pressures according to the results of rheological and differential scanning calorimetry test. Laminates were cured in autoclave process following the processing conditions designed. Then the cured laminates were inspected by ultrasonic c-scan and areas with uniformed porosity distribution within each plate were trimmed down and used for porosity assessment and mechanical strength test. The experimental results show that there exists an optimum moment for applying autoclave pressure for the studied, composite material and an improved cure cycle was finally obtained according to the testing data of interlaminar shear strength and fiexural strength.
| Original language | English |
|---|---|
| Pages | 3137-3144 |
| Number of pages | 8 |
| State | Published - 2004 |
| Externally published | Yes |
| Event | SAMPE 2004 - Long Beach, CA, United States Duration: 16 May 2004 → 20 May 2004 |
Conference
| Conference | SAMPE 2004 |
|---|---|
| Country/Territory | United States |
| City | Long Beach, CA |
| Period | 16/05/04 → 20/05/04 |
Keywords
- Autoclave cure
- Mechanical strength
- Porosity
- Ultrasonic inspection
Fingerprint
Dive into the research topics of 'Influences of processing conditions on porosity for the autoclave cure of composites'. Together they form a unique fingerprint.Cite this