Skip to main navigation Skip to search Skip to main content

Influence of Polarization Crosstalk of y Branch Loop on Scale Factor in Fiber Optic Current Sensor

  • Beijing Engineering Research Center of Photoelectric Information and Instrument
  • National Institute of Metrology China

Research output: Contribution to journalConference articlepeer-review

Abstract

The influence of polarization crosstalk of Y branch loop on scale factor is analyzed in detail. In the Y branch loop, the scale factor is affected by only the output alignment angle of the PBS. The experiment result shows the range of output alignment angle of the PBS should not exceed from 0.2 to 2.5 over a range from - 40 C to 70 C which corresponds to angle 1.8 at room temperature to make sure the measurement accuracy within 0.2% from 0 to 100kA.

Original languageEnglish
Article number052120
JournalJournal of Physics: Conference Series
Volume1549
Issue number5
DOIs
StatePublished - 29 Jun 2020
Externally publishedYes
Event2020 International Conference on Environment Science and Advanced Energy Technologies, ESAET 2020 - Chongqing, China
Duration: 18 Jan 202019 Jan 2020

Fingerprint

Dive into the research topics of 'Influence of Polarization Crosstalk of y Branch Loop on Scale Factor in Fiber Optic Current Sensor'. Together they form a unique fingerprint.

Cite this