Skip to main navigation Skip to search Skip to main content

Improvements of tooth movement efficiency and torque control in expanding the arch with clear aligners: a finite element analysis

  • Song Yao
  • , Wei Jiang
  • , Chunjuan Wang
  • , Yao He
  • , Chao Wang
  • , Lan Huang*
  • *Corresponding author for this work
  • Chongqing Medical University
  • Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences
  • Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education

Research output: Contribution to journalArticlepeer-review

Abstract

Objectives: The purpose of this study was to analyze the effect of different movement strategies, embossment structures, and torque compensation of the aligner on tooth movement during arch expansion using clear aligners by finite element analysis. Methods: Models comprising the maxilla, dentition, periodontal ligament, and aligners were created and imported into a finite element analysis software. The tests were performed using the following: three orders of tooth movement (including alternating movement with the first premolar and first molar, whole movement with second premolar and first molar or premolars and first molar), four different shapes of embossment structures (ball, double ball, cuboid, cylinder, with 0.05, 0.1, 0.15-mm interference) and torque compensation (0°, 1°, 2°, 3°, 4°, and 5°). Results: The expansion of clear aligners caused the target tooth to move obliquely. Alternating movement resulted in higher movement efficiency with lower anchorage loss as compared with whole movement. Embossment increased the efficiency of crown movement but did not contribute positively to torque control. As the angle of compensation increased, the tendency of oblique tooth movement was gradually controlled; however, the movement efficiency decreased concurrently, and stress distribution on the periodontal ligament became more even. For each 1° increase in compensation, the torque per millimeter of the first premolar would decrease by 0.26°/mm, and the crown movement efficiency eliminate decreased by 4.32%. Conclusion: Alternating movement increases the efficiency of the arch expansion by the aligner and reduces anchorage loss. Torque compensation should be designed to enhance torque control in arch expansion using an aligner.

Original languageEnglish
Article number1120535
JournalFrontiers in Bioengineering and Biotechnology
Volume11
DOIs
StatePublished - 2023

Keywords

  • arch expansion
  • clear aligner
  • finite element analysis
  • tooth movement strategies
  • torque compensation

Fingerprint

Dive into the research topics of 'Improvements of tooth movement efficiency and torque control in expanding the arch with clear aligners: a finite element analysis'. Together they form a unique fingerprint.

Cite this