Imaging gas-solids distribution in cyclone inlet of circulating fluidised bed with rectangular ECT sensor

  • Haigang Wang*
  • , Xiaofang Wang
  • , Qinggang Lu
  • , Yunkai Sun
  • , Wuqiang Yang
  • *Corresponding author for this work

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

Abstract

A rectangular electrical capacitance tomography (ECT) sensor has been designed and used to measure the solids distribution in a cross-section in an inlet of cyclone separator for a supper-critical pressure circulating fluidised bed (CFB). The ECT sensor has twelve electrodes with two in each shorter side and four in each longer side. For image reconstruction, sensitivity maps have been calculated using a simulation package, Maxwell from Ansoft. Static test results are analysed in terms of standard deviation and image error. CFD simulation results for the solid distribution in the cyclone are given and future work for dynamics test of CFB processes with rectangular ECT sensor are given in the end of the paper.

Original languageEnglish
Title of host publication2011 IEEE International Conference on Imaging Systems and Techniques, IST 2011 - Proceedings
Pages55-59
Number of pages5
DOIs
StatePublished - 2011
Externally publishedYes
Event2011 IEEE International Conference on Imaging Systems and Techniques, IST 2011 - Batu Ferringhi, Penang, Malaysia
Duration: 17 May 201118 May 2011

Publication series

Name2011 IEEE International Conference on Imaging Systems and Techniques, IST 2011 - Proceedings

Conference

Conference2011 IEEE International Conference on Imaging Systems and Techniques, IST 2011
Country/TerritoryMalaysia
CityBatu Ferringhi, Penang
Period17/05/1118/05/11

Keywords

  • Cyclone separators
  • ECT
  • Fluidised bed
  • Rectangular sensor

Fingerprint

Dive into the research topics of 'Imaging gas-solids distribution in cyclone inlet of circulating fluidised bed with rectangular ECT sensor'. Together they form a unique fingerprint.