Ignition and lean blow out performance of TVC with different fuel-air matching forms

  • Fei Xing*
  • , Wei Jun Fan
  • , Yang Liu
  • , Zhao Jian Kong
  • , Mao Lin Yang
  • *Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

Abstract

To investigated the lean ignition and lean blow out performance of a trapped vortex combustor ( TVC) test rig, abundant experiments have been employed in variety inlet conditions. There are four forebody cases for the TVC with kerosene as fuel. The results of the experiment indicate that; with the air of the after body increased, ignition fuel air ratio increased first and then turned down; at most operation conditions, ignition fuel air ratio is under 0. 04; lean blow-out fuel air ratio increased and turned down with main air decreased; the blow-out fuel air ratio of all the cases were less than 0. 004. Rising the temperature of fore-wall is good for ignition and LBO.

Original languageEnglish
Pages (from-to)412-416+421
JournalTuijin Jishu/Journal of Propulsion Technology
Volume29
Issue number4
StatePublished - Aug 2008

Keywords

  • Fore-wall changed
  • Lean blow-out
  • Lean ignition
  • Trapped vortex combustor

Fingerprint

Dive into the research topics of 'Ignition and lean blow out performance of TVC with different fuel-air matching forms'. Together they form a unique fingerprint.