Skip to main navigation Skip to search Skip to main content

Human-level comparable control volume mapping with a deep unsupervised-learning model for image-guided radiation therapy

  • Xiaokun Liang
  • , Maxime Bassenne
  • , Dimitre H. Hristov
  • , Md Tauhidul Islam
  • , Wei Zhao
  • , Mengyu Jia
  • , Zhicheng Zhang
  • , Michael Gensheimer
  • , Beth Beadle
  • , Quynh Le
  • , Lei Xing*
  • *Corresponding author for this work
  • Stanford University

Research output: Contribution to journalArticlepeer-review

Abstract

Purpose: To develop a deep unsupervised learning method with control volume (CV) mapping from patient positioning daily CT (dCT) to planning computed tomography (pCT) for precise patient positioning. Methods: We propose an unsupervised learning framework, which maps CVs from dCT to pCT to automatically generate the couch shifts, including translation and rotation dimensions. The network inputs are dCT, pCT and CV positions in the pCT. The output is the transformation parameter of the dCT used to setup the head and neck cancer (HNC) patients. The network is trained to maximize image similarity between the CV in the pCT and the CV in the dCT. A total of 554 CT scans from 158 HNC patients were used for the evaluation of the proposed model. At different points in time, each patient had many CT scans. Couch shifts are calculated for the testing by averaging the translation and rotation from the CVs. The ground-truth of the shifts come from bone landmarks determined by an experienced radiation oncologist. Results: The system positioning errors of translation and rotation are less than 0.47 mm and 0.17°, respectively. The random positioning errors of translation and rotation are less than 1.13 mm and 0.29°, respectively. The proposed method enhanced the proportion of cases registered within a preset tolerance (2.0 mm/1.0°) from 66.67% to 90.91% as compared to standard registrations. Conclusions: We proposed a deep unsupervised learning architecture for patient positioning with inclusion of CVs mapping, which weights the CVs regions differently to mitigate any potential adverse influence of image artifacts on the registration. Our experimental results show that the proposed method achieved efficient and effective HNC patient positioning.

Original languageEnglish
Article number105139
JournalComputers in Biology and Medicine
Volume141
DOIs
StatePublished - Feb 2022
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Head and neck
  • Image registration
  • Image-guided radiation therapy
  • Patient positioning
  • Unsupervised learning

Fingerprint

Dive into the research topics of 'Human-level comparable control volume mapping with a deep unsupervised-learning model for image-guided radiation therapy'. Together they form a unique fingerprint.

Cite this