Abstract
Nitrogen-doped mesocellular carbon foam (denoted as MCF-CN,) with high surface area and large pore volume was prepared and characterized in detail. The MCF-CN, was further functionalized by oxidation with HNO3 (denoted as MCF - CNx-O) in order to effectively improve its hydrophilicity and biocompatibility. Both MCF-CN, and MCF - CNx-O were used for immobilization of Hb and design of electrochemical biosensors. The activity of Hb immobilized on MCF - CNx-O is two times higher than that of Hb immobilized on MCF-CN, The Hb-MCF - CNx-O-Nafion modified electrode displays fast response, high sensitivity and low detection limit to the detection of hydrogen peroxide. The sensitivity of Hb-MCF - CN x-O-Nafion modified electrode (477 μA mM-1 cm -2) is twice that of Hb-MCF - CNx-Nafion modified electrode.
| Original language | English |
|---|---|
| Pages (from-to) | 715-722 |
| Number of pages | 8 |
| Journal | Electroanalysis |
| Volume | 21 |
| Issue number | 6 |
| DOIs | |
| State | Published - Mar 2009 |
| Externally published | Yes |
Keywords
- Hemoglobin
- High performance
- Immobilization
- Nitrogen-doped mesocellular carbon foam
Fingerprint
Dive into the research topics of 'High performance oxide functionalized nitrogen-doped mesocellular carbon foam for biosensor construction'. Together they form a unique fingerprint.Cite this