Skip to main navigation Skip to search Skip to main content

Gas-Liquid Two-Phase Flow Measurement Using Coriolis Flowmeters Incorporating Artificial Neural Network, Support Vector Machine, and Genetic Programming Algorithms

  • Lijuan Wang
  • , Jinyu Liu
  • , Yong Yan*
  • , Xue Wang
  • , Tao Wang
  • *Corresponding author for this work
  • School of Engineering and Digital Arts
  • University of Kent
  • School of Mathematics
  • KROHNE Messtechnik GmbH

Research output: Contribution to journal › Article › peer-review

Abstract

Coriolis flowmeters are well established for the mass flow measurement of single-phase flow with high accuracy. In recent years, attempts have been made to apply Coriolis flowmeters to measure two-phase flow. This paper presents data driven models that are incorporated into Coriolis flowmeters to measure both the liquid mass flowrate and the gas volume fraction of a two-phase flow mixture. Experimental work was conducted on a purpose-built two-phase flow test rig on both horizontal and vertical pipelines for a liquid mass flowrate ranging from 700 to 14500 kg/h and a gas volume fraction between 0% and 30%. Artificial neural network (ANN), support vector machine (SVM), and genetic programming (GP) models are established through training with the experimental data. The performance of backpropagation-ANN (BP-ANN), radial basis function-ANN (RBF-ANN), SVM, and GP models is assessed and compared. Experimental results suggest that the SVM models are superior to the BP-ANN, RBF-ANN, and GP models for two-phase flow measurement in terms of robustness and accuracy. For liquid mass flowrate measurement with the SVM models, 93.49% of the experimental data yield a relative error less than ±1% on the horizontal pipeline, while 96.17% of the results are within ±1% on the vertical installation. The SVM models predict the gas volume fraction with a relative error less than ±10% for 93.10% and 94.25% of the test conditions on the horizontal and vertical installations, respectively.

Original languageEnglish
Article number7790803
Pages (from-to)852-868
Number of pages17
JournalIEEE Transactions on Instrumentation and Measurement
Volume66
Issue number5
DOIs
StatePublished - May 2017
Externally publishedYes

Keywords

  • Artificial neural network (ANN)
  • Coriolis mass flowmeter
  • flow measurement
  • gas volume fraction
  • genetic programming (GP)
  • support vector machine (SVM)
  • two-phase flow

Fingerprint

Dive into the research topics of 'Gas-Liquid Two-Phase Flow Measurement Using Coriolis Flowmeters Incorporating Artificial Neural Network, Support Vector Machine, and Genetic Programming Algorithms'. Together they form a unique fingerprint.

Cite this