Abstract

A novel anti-fouling epoxy-silicone composite coating containing Ni-Cu-Al alloy powder for metal pipeline in geothermal water was fabricated based on the basic principles of galvanic corrosion. Fouling behaviors of the surface of composite coating in the simulated geothermal water were studied in comparison with stainless steel and epoxy-silicone resin coating. The results indicated that composite coating possessed a good anti-fouling performance. In the geothermal water, Ni 2+, Cu 2+ and Al 3+ ions, originated from interface electrochemical corrosion, were released into bulk solution. These metal ions intensively inhibited nucleation and crystal growth rate of CaCO 3 fouling on the surface of composite coating, and promoted precipitation of CaCO 3 fouling in the bulk-solution, which could be easily washed away by flowing water. But for 304 stainless-steel and epoxy-silicone resin coating, CaCO 3 fouling grew easily and adhered firmly to their surfaces, and influenced the transport efficiency of geothermal water for pipelines.

Original languageEnglish
Pages (from-to)3728-3732
Number of pages5
JournalSurface and Coatings Technology
Volume206
Issue number18
DOIs
StatePublished - 15 May 2012

Keywords

  • Anti-fouling
  • CaCO fouling
  • Composite coating
  • Galvanic corrosion
  • Surfaces

Fingerprint

Dive into the research topics of 'Galvanic corrosion of Ni-Cu-Al composite coating and its anti-fouling property for metal pipeline in simulated geothermal water'. Together they form a unique fingerprint.

Cite this