Skip to main navigation Skip to search Skip to main content

Fitting curve passing through designated point to data for promoting the reproducibility of peripheral quantitative computed tomography (pQCT)

  • Beihang University

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

Abstract

The Peripheral quantitative computed tomography (pQCT) is increasingly being used to monitor bone mineral density (BMD) change in both research and clinical practice in order to evaluate the fracture susceptibility in old people or the effect following therapeutic intervention[3]. In follow-up studies, the drift area (change area) of total cross-sectional area (CSA) comparing with that of the baseline measurement (first measurement) was used to control the position as the baseline measurement. To study the interrelationship between the apparent BMD change and CSA change, the nonlinear regression curve was required to pass through a designated point. However, there is no ready-made software that can give the regression model which can pass through a designated point. In this study, BMD at 21 skeletal locations around 4% length of radius were measured by pQCT, then linear and nonlinear regression models passing through designated point were set up based on least square method using Matlab. The results showed the logarithmic model y = 23.4009-5.92491n(x + 51.9140) was suitable to describe the relationship between BMD change and cross-sectional area (CSA) change at the distal radius. This will be helpful to promote the reproducibility of pQCT in follow-up measurements.

Original languageEnglish
Title of host publicationBioMedical Engineering and Informatics
Subtitle of host publicationNew Development and the Future - Proceedings of the 1st International Conference on BioMedical Engineering and Informatics, BMEI 2008
PublisherIEEE Computer Society
Pages867-871
Number of pages5
ISBN (Print)9780769531182
DOIs
StatePublished - 2008
Event1st International Conference on BioMedical Engineering and Informatics, BMEI 2008, co-located with the 1st International Congress on Image and Signal Processing, CISP 2008 - Sanya, Hainan, China
Duration: 27 May 200830 May 2008

Publication series

NameBioMedical Engineering and Informatics: New Development and the Future - Proceedings of the 1st International Conference on BioMedical Engineering and Informatics, BMEI 2008
Volume2

Conference

Conference1st International Conference on BioMedical Engineering and Informatics, BMEI 2008, co-located with the 1st International Congress on Image and Signal Processing, CISP 2008
Country/TerritoryChina
CitySanya, Hainan
Period27/05/0830/05/08