Skip to main navigation Skip to search Skip to main content

Film cooling effectiveness of a leading-edge cooling array of a rotating turbine blade with twist

  • Feng Han
  • , Shuai Bi
  • , Jun kui Mao*
  • , Hai wang Li
  • *Corresponding author for this work
  • Nanjing University of Aeronautics and Astronautics

Research output: Contribution to journalArticlepeer-review

Abstract

Experimental investigations have been carried out to study the effects of the film hole pitch-to-diameter ratio (P/D), blowing ratio (M) and rotation on the leading edge (LE) region film cooling performance of a twist turbine blade under rotating conditions. The thermochromic liquid crystal (TLC) technology was applied to measure the LE surface temperature. All experiments were performed at the rotating speed of 574 r/min with the average M varying from 0.5 to 1.25. The Reynolds number (Re) based on the mainstream velocity of the turbine outlet and the test blade chord length was maintained at 6.4 × 104. The coolant-to-mainstream density ratio (DR) was 1.04 with N2 as the coolant. The hole pitch-to-diameter ratios tested were P/D = 2.5, P/D = 3.75 and P/D = 5.0, respectively. The experimental results indicate that both the P/D and the M play an indispensable role in influencing the film cooling performance on the LE under rotating conditions. Regardless of the value of film hole P/D, the spanwise average film cooling effectiveness (η) increases gradually with increasing the M on the LE region under rotating conditions. For all hole P/D cases, the experimental results indicate that the level of spanwise average η provided by the PS region (-4.3 < X/D < 0) is higher than that provided by the SS region (0 < X/D < 3.75) in the LE region when the M was unchanged under rotating conditions. For all M cases, the spanwise average η indicates the decreasing trend with increasing the hole P/D. For all hole P/D cases, the area average η increases gradually with increasing the M. For all M cases, the area average η decreases gradually with increasing the hole P/D. And the reduction is sometimes non-linear to the P/D change. Under the condition that the coolant jet mass flow rate (MFR) remains constant, the area average η decreases gradually with increasing the hole P/D.

Original languageEnglish
Article number120175
JournalApplied Thermal Engineering
Volume225
DOIs
StatePublished - 5 May 2023

Keywords

  • Effectiveness
  • Film cooling
  • Hole pitch-to-diameter ratio
  • Leading edge
  • Rotating blade

Fingerprint

Dive into the research topics of 'Film cooling effectiveness of a leading-edge cooling array of a rotating turbine blade with twist'. Together they form a unique fingerprint.

Cite this