Fast System Matrix Generation Based on Single Angle Calibration in Open-Sided Field Free Line Magnetic Particle Imaging

  • Guanghui Li
  • , Yanjun Liu
  • , Zhumei Qian
  • , Fei Xiong
  • , Siao Lei
  • , Yuan Feng
  • , Jiaqian Li
  • , Yang Du*
  • , Jie Tian*
  • , Yu An*
  • *Corresponding author for this work
  • Beihang University
  • Chinese Academy of Sciences
  • University of Chinese Academy of Sciences

Research output: Contribution to journalArticlepeer-review

Abstract

Objective: Open-sided field-free line magnetic particle imaging (OS FFL MPI) is a novel medical imaging system configuration that has received significant attention in recent years. However, the measurement-based system matrix (SM) image reconstruction for OS FFL MPI typically requires multiple angle calibration (MAC), which is time-consuming in practice. Methods: To address this issue, we propose a fast 2D SM generation method that requires only a single angle calibration (SAC). The SAC method exploits the rotational invariance of the system function. Based on the measured single angle system function, the system function is rotated to generate system functions at other angles, and then the SM for image reconstruction is constructed. Then, we conducted various simulation experiments and built an OS FFL MPI scanner to evaluate the proposed SAC method. Results: The experiments demonstrating the effectiveness of SAC in reducing calibration workload, requiring fewer scanning numbers while maintaining a similar image reconstruction quality compared to MAC method. Furthermore, the SM generated by SAC produces consistent imaging results with the SM generated by MAC, regardless of the interpolation algorithms, the number of rotation angles, or the signal-to-noise ratios employed in phantom imaging experiments. Conclusion: SAC has been experimentally verified to reduce acquisition time while maintaining accurate and robust reconstruction performance. Significance: The significance of SAC lies in its contribution to improving calibration efficiency in OS FFL MPI, potentially facilitating the implementation of MPI in a wider range of applications.

Original languageEnglish
Pages (from-to)1209-1218
Number of pages10
JournalIEEE Transactions on Biomedical Engineering
Volume71
Issue number4
DOIs
StatePublished - 1 Apr 2024

Keywords

  • Magnetic particle imaging
  • open-sided field free line
  • system functions
  • system matrix

Fingerprint

Dive into the research topics of 'Fast System Matrix Generation Based on Single Angle Calibration in Open-Sided Field Free Line Magnetic Particle Imaging'. Together they form a unique fingerprint.

Cite this