Experimental study on the turbine blade cooling channel with crossed-ribs

  • Hong Wu Deng*
  • , Yan Tan
  • , Jia Ren Wang
  • , Ji Ning Sun
  • *Corresponding author for this work
  • Beihang University

Research output: Contribution to journalArticlepeer-review

Abstract

The characteristics of heat transfer and flow resistance in turbine blade cooling channel were studied experimentally with use of vapor heating method, which could provide the experimental model with equivalent wall temperature boundary condition. The experiments were carried out under the condition that the Re was 10000~60000. The experiment models adopted the structure of crossed-ribs, pin-fins and longitudinal dividers. The outside wall was divided into ten regions and the condensation vapor of the regions was gathered to get the local heat transfer coefficient. The results show that the crossed-ribs channel could lead to better heat performance than the pin-fins channel. The results also show that, in the case of Re<30000, the structure with the best general heat transfer performance is crossed-ribs channel of 0612, and in the case of Re>30000, the best one is crossed-ribs channel of 0412.

Original languageEnglish
Pages (from-to)1931-1937
Number of pages7
JournalHangkong Dongli Xuebao/Journal of Aerospace Power
Volume25
Issue number9
StatePublished - Sep 2010

Keywords

  • Crossed-ribs
  • Flow and heat transfer
  • Flowing resistance
  • Longitudinal dividers
  • Turbine blade

Fingerprint

Dive into the research topics of 'Experimental study on the turbine blade cooling channel with crossed-ribs'. Together they form a unique fingerprint.

Cite this