Skip to main navigation Skip to search Skip to main content

Experiment on multi-tooth rim sealing

  • Beihang University

Research output: Contribution to journalArticlepeer-review

Abstract

The gas volume fraction method was used to achieve the distribution of the sealing effectiveness of multi-tooth rim sealing, and the sealing effectiveness varied with the non-dimensional sealing flow rate, and finally the correlation of the minimum sealing flow rate was obtained(mainstream Reynold number from 1.42×105 to 3.20×105, rotating Reynold number from 5.27×105 to 1.36×106). The measurement results of carbon dioxide volume fraction showed that the sealing effectiveness was low at high radius but high at low radius. The changes in the sealing effectiveness with the sealing flow rate agreed well with Owen's sealing effectiveness equations, so the sealing characteristic could be predicted, and the experimental results expanded its application scope.

Original languageEnglish
Pages (from-to)8-13
Number of pages6
JournalHangkong Dongli Xuebao/Journal of Aerospace Power
Volume32
Issue number1
DOIs
StatePublished - 1 Jan 2017

Keywords

  • Gas ingestion
  • Minimum sealing flow rate
  • Multi-tooth rim sealing
  • Sealing effectiveness
  • Volume fraction method

Fingerprint

Dive into the research topics of 'Experiment on multi-tooth rim sealing'. Together they form a unique fingerprint.

Cite this