Skip to main navigation Skip to search Skip to main content

Evaluation for sulfide stress corrosion cracking of cold-high pressure segregator

  • Ming Li*
  • , Xiaogang Li
  • , Gang Chen
  • , Yang Hu
  • , Guangting Xue
  • *Corresponding author for this work
  • University of Science and Technology Beijing
  • China Special Equipment Inspection and Research Institute
  • SINOPEC

Research output: Contribution to journal › Article › peer-review

Abstract

An incorrect hole on a cold-high pressure segregator was plugged up by welding. The cold-high pressure segregator runs in the environment of high pressure and high H2S. Accordingly, the accident of sulfide stress corrosion cracking (SSCC) should be taken into account. The SSCC sensitivity and cracking time of 16Mn(HIC) steel used to make the cold-high pressure segregator and common 16Mn steel in solutions with various H2S contents and pH values, simulated solution and operating solution were investigated by constant strain bend and slow strain rate test (SSRT). Hydrogen diffusion coefficients of 16Mn (HIC) steel, 16Mn steel and their welded seams were also tested by the electrolyte hydrogen charged method. Safety evaluation of the cold-high pressure segregator was given with above results.

Original languageEnglish
Pages (from-to)2997-3004
Number of pages8
JournalHuagong Xuebao/CIESC Journal
Volume57
Issue number12
StatePublished - Dec 2006
Externally publishedYes

Keywords

  • 16Mn steel
  • Cold-high pressure segregator
  • Evaluation
  • Sulfide stress corrosion cracking

Fingerprint

Dive into the research topics of 'Evaluation for sulfide stress corrosion cracking of cold-high pressure segregator'. Together they form a unique fingerprint.

Cite this