Abstract
An incorrect hole on a cold-high pressure segregator was plugged up by welding. The cold-high pressure segregator runs in the environment of high pressure and high H2S. Accordingly, the accident of sulfide stress corrosion cracking (SSCC) should be taken into account. The SSCC sensitivity and cracking time of 16Mn(HIC) steel used to make the cold-high pressure segregator and common 16Mn steel in solutions with various H2S contents and pH values, simulated solution and operating solution were investigated by constant strain bend and slow strain rate test (SSRT). Hydrogen diffusion coefficients of 16Mn (HIC) steel, 16Mn steel and their welded seams were also tested by the electrolyte hydrogen charged method. Safety evaluation of the cold-high pressure segregator was given with above results.
| Original language | English |
|---|---|
| Pages (from-to) | 2997-3004 |
| Number of pages | 8 |
| Journal | Huagong Xuebao/CIESC Journal |
| Volume | 57 |
| Issue number | 12 |
| State | Published - Dec 2006 |
| Externally published | Yes |
Keywords
- 16Mn steel
- Cold-high pressure segregator
- Evaluation
- Sulfide stress corrosion cracking
Fingerprint
Dive into the research topics of 'Evaluation for sulfide stress corrosion cracking of cold-high pressure segregator'. Together they form a unique fingerprint.Cite this