T1 - Enhanced ambient pressure sensitivity of the subharmonic signal from ultrasound contrast microbubbles
AU - Li, Fei
AU - Cai, Feiyan
AU - Meng, Long
AU - Jin, Qiaofeng
AU - Zhen, Hairong
AU - Li, Deyu
PY - 2013
Y1 - 2013
N2 - Microbubble ultrasound contrast agent (UCA) has been well recognized as a potential noninvasive tool for the blood pressure measurement. A decrease in subharmonic amplitude of 9 to 12 dB has been reported for Levovist, Optison, Definity, Sonazoid, and SonoVue for ambient overpressure values around 180 mmHg. However, a pressure resolution of 3 mmHg is desirable in medical diagnostics, it is still necessary to enhance the pressure sensitivity for the method based on the subharmonic amplitude as a function of local pressure. The purpose of this study was to improve the ambient pressure sensitivity of the subharmonic amplitude by optimizing acoustic parameters in in vitro experiments. The acoustic scattering measurement was carried out at different acoustic parameters, and it was demonstrated for SonoVue by us that the subharmonic amplitude reduced by 10.9 dB at the driving frequency of 4 MHz and the acoustic pressure of 450 kPa (mechanical index MI = 0.225), 19.8 dB at 4 MHz and 500 kPa (MI = 0.25), and 17.6 dB at 1.33 MHz and 350 kPa (MI = 0.3), respectively, when the overpressure increased to 180 mmHg. The results showed the effect of the mechanical index on the ambient pressure sensitivity of subharmonic amplitude, and indicated the existence of a MI threshold ( ≈ 0.23) at which the sensitivity can be enhanced significantly.
AB - Microbubble ultrasound contrast agent (UCA) has been well recognized as a potential noninvasive tool for the blood pressure measurement. A decrease in subharmonic amplitude of 9 to 12 dB has been reported for Levovist, Optison, Definity, Sonazoid, and SonoVue for ambient overpressure values around 180 mmHg. However, a pressure resolution of 3 mmHg is desirable in medical diagnostics, it is still necessary to enhance the pressure sensitivity for the method based on the subharmonic amplitude as a function of local pressure. The purpose of this study was to improve the ambient pressure sensitivity of the subharmonic amplitude by optimizing acoustic parameters in in vitro experiments. The acoustic scattering measurement was carried out at different acoustic parameters, and it was demonstrated for SonoVue by us that the subharmonic amplitude reduced by 10.9 dB at the driving frequency of 4 MHz and the acoustic pressure of 450 kPa (mechanical index MI = 0.225), 19.8 dB at 4 MHz and 500 kPa (MI = 0.25), and 17.6 dB at 1.33 MHz and 350 kPa (MI = 0.3), respectively, when the overpressure increased to 180 mmHg. The results showed the effect of the mechanical index on the ambient pressure sensitivity of subharmonic amplitude, and indicated the existence of a MI threshold ( ≈ 0.23) at which the sensitivity can be enhanced significantly.
KW - Microbubble
KW - Pressure sensitivity
KW - Subharmonic
KW - Ultrasound
UR - https://www.scopus.com/pages/publications/84894351533
U2 - 10.1109/ULTSYM.2013.0084
DO - 10.1109/ULTSYM.2013.0084
M3 - 会议稿件
AN - SCOPUS:84894351533
SN - 9781467356862
T3 - IEEE International Ultrasonics Symposium, IUS
SP - 325
EP - 328
BT - 2013 IEEE International Ultrasonics Symposium, IUS 2013
T2 - 2013 IEEE International Ultrasonics Symposium, IUS 2013
Y2 - 21 July 2013 through 25 July 2013
ER -