Distributed spaceborne InSAR DEM calibration

  • Liang Feng*
  • , Huaping Xu
  • , Chunsheng Li
  • *Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

Abstract

The residue error will be transferred to the elevation data during the acquirement of DEM data with distributed satellite SAR, which makes the accuracy fail to meet the need of system design. The systematic errors can be effectively reduced by the calibration method based on ground control points (GCPs), but inherent errors of control points will be transferred to the elevation data as well. Therefore, it is significant to determine the number of control points in a data take period and their layout in DEM calibration method. A method to forecast errors of DEM is proposed in this paper, and the formula of elevation data's standard deviation is deduced according to analysis of DEM calibration method and GCP location and accuracy. On basis of approaches mentioned above, the layout regulation of GCPs can be studied efficiently. The approaches are validated by digital simulation.

Original languageEnglish
Pages (from-to)109-113
Number of pages5
JournalYi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument
Volume32
Issue number12 SUPPL.
StatePublished - Dec 2011

Keywords

  • DEM calibration
  • Distributed InSAR
  • Ground control point
  • Height errors

Fingerprint

Dive into the research topics of 'Distributed spaceborne InSAR DEM calibration'. Together they form a unique fingerprint.