Skip to main navigation Skip to search Skip to main content

DGCD-3D: Difference-guided conditional diffusion model for low-field 3D MRI enhancement to assist stroke assessment

  • Hao Li
  • , Ziyang Liu
  • , Yu Zhou
  • , Shuo Zhang
  • , Shaodong Ding
  • , Xuewei Xie
  • , Wanlin Zhu
  • , Chong Han
  • , Zhe Zhang
  • , Yue Suo
  • , Zheng Li
  • , Yongjun Wang
  • , Guanglei Zhang
  • , Jing Jing
  • , Tao Liu*
  • *Corresponding author for this work
  • Beihang University
  • Ltd.
  • Capital Medical University

Research output: Contribution to journalArticlepeer-review

Abstract

Low-field (LF) magnetic resonance imaging (MRI) plays a crucial role in assisting clinicians with rapid stroke diagnosis. However, its inherent limitations, such as low signal-to-noise ratio (SNR) and suboptimal image quality, make accurate stroke lesion identification challenging. To address this, we propose a Difference-Guided Conditional Diffusion Model (DGCD-3D) to enhance image quality of LF MRI while preserving structural integrity of stroke lesions. Specifically, the model incorporates a difference-adaptive forward diffusion process that guides the diffusion dynamics based on differences. During training, multi-scale intrinsic features from LF MRI and prior spatial information of stroke lesions are explicitly encoded into the generative process. Furthermore, a time-adaptive multi-loss optimization strategy dynamically balances pixel-wise and perceptual losses at different timesteps. DGCD-3D was evaluated on a large-scale, clinically scarce paired LF–HF MRI dataset (n = 974) acquired within a mean interval of 18.5 min. Experimental results demonstrate that DGCD-3D substantially improves LF MRI image quality (PSNR = 28.26, SSIM = 0.896) and achieves significantly higher consistency with HF MRI in stroke lesion assessment (Spearman’s correlation coefficient ρ = 0.732) compared with the LF MRI (ρ = 0.680). Furthermore, a clinical authenticity assessment conducted by six experienced radiologists yielded a confusion rate of 51.6% and a confusion score of 5.64, further confirming the clinical reliability and broad applicability of the proposed approach. The codes and trained models will be released on GitHub: https://github.com/lihao9056/DGCD-3D .

Original languageEnglish
Article number104183
JournalMedical Image Analysis
Volume113
DOIs
StatePublished - Sep 2026

Keywords

  • Deep learning
  • Diffusion model
  • Image quality enhancement
  • Ischemic stroke

Fingerprint

Dive into the research topics of 'DGCD-3D: Difference-guided conditional diffusion model for low-field 3D MRI enhancement to assist stroke assessment'. Together they form a unique fingerprint.

Cite this