Abstract
This paper reports the design, simulation, and analysis of a new kind of superconducting loop working as a flux-to-field transformer that is based on the superconducting magnetic flux change theory and the characteristics of ultrasensitive GMI/superconducting mixed sensors. The theoretical derivation of the transformer's expected properties is introduced and the design and fabrication of the mixed sensor are optimized to achieve high sensitivity. Compared with previous structures, this new transformer has great advantages for the enhancement of weak magnetic fields and noise suppression in theory.
| Original language | English |
|---|---|
| Pages | 414-417 |
| Number of pages | 4 |
| DOIs | |
| State | Published - 2013 |
| Event | 2013 IEEE International Conference on Applied Superconductivity and Electromagnetic Devices, ASEMD 2013 - Beijing, China Duration: 25 Oct 2013 → 27 Oct 2013 |
Conference
| Conference | 2013 IEEE International Conference on Applied Superconductivity and Electromagnetic Devices, ASEMD 2013 |
|---|---|
| Country/Territory | China |
| City | Beijing |
| Period | 25/10/13 → 27/10/13 |
Keywords
- low noise
- optimization
- superconducting loop
- ultra-sensitive mixed sensor
Fingerprint
Dive into the research topics of 'Design and simulation of a magnetic flux-to-field transformer for GMI/superconducting mixed magnetometer application'. Together they form a unique fingerprint.Cite this