Abstract
This paper carries out a comparison of motor loss between PMSMs driven by SiC inverter and Si inverter. Motor loss is firstly modeled. Then, a 2-D FEM analysis is conducted to compare the loss value and iron loss distribution caused by different input current waveforms provided by SiC inverter and Si inverter respectively. In order to validate the simulation result, an experiment platform is established and the comparison based on the test data is carried out with the method of 3-D efficiency map. The result exhibits that under whole operating conditions, the motor driven by SiC inverter shows an obviously lower loss than the one driven by Si inverter. Therefore, the superiority of SiC inverter on motor loss reduction is proved.
| Original language | English |
|---|---|
| State | Published - 2018 |
| Event | CSAA/IET International Conference on Aircraft Utility Systems, AUS 2018 - Guiyang, China Duration: 19 Jun 2018 → 22 Jun 2018 |
Conference
| Conference | CSAA/IET International Conference on Aircraft Utility Systems, AUS 2018 |
|---|---|
| Country/Territory | China |
| City | Guiyang |
| Period | 19/06/18 → 22/06/18 |
Keywords
- Aircrafts
- Current distortion
- Motor loss
- Si
- SiC
Fingerprint
Dive into the research topics of 'Comparison of motor loss between PMSMs driven by SiC inverter and Si inverter'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver