Skip to main navigation Skip to search Skip to main content

Combining vibrotactile feedback with volitional myoelectric control for robotic transtibial prostheses

  • Baojun Chen
  • , Yanggang Feng
  • , Qining Wang*
  • *Corresponding author for this work
  • Peking University

Research output: Contribution to journalArticlepeer-review

Abstract

In recent years, the development of myoelectric control for robotic lower-limb prostheses makes it possible for amputee users to volitionally control prosthetic joints. However, the human-centered control loop is not closed due to the lack of sufficient feedback of pros-Thetic joint movement, and it may result in poor control performance. In this research, we propose a vibrotactile stimulation system to provide the feedback of ankle joint position, and validate the necessity of combining it with volitional myoelectric control to achieve improved control performance. The stimulation system is wearable and consists of six vibrators. Three of the vibrators are placed on the anterior side of the thigh and the other three on the posterior side of the thigh. To explore the potential of applying the proposed vibrotactile feedback system for prosthetic ankle control, eight able-bodied subjects and two transtibial amputee subjects (TT1 and TT2) were recruited in this research, and several experiments were designed to investigate subjects' sensitivities to discrete and continuous vibration stimulations applied on the thigh. Then, we proposed a stimulation controller to produce different stimulation patterns according to current ankle angle. Amputee subjects were asked to control a virtual ankle displayed on the computer screen to reach different target ankle angles with a myoelectric controller, and control performances under different feedback conditions were compared. Experimental results indicated that subjects were more sensitive to stimulation position changes (identification accuracies were 96.39 ± 0.86, 91.11, and 93.89% for able-bodied subjects, TT1, and TT2, respectively) than stimulation amplitude changes (identification accuracies were 89.89 ± 2.40, 87.04, and 85.19% for able-bodied subjects, TT1, and TT2, respectively). Response times of able-bodied subjects, TT1, and TT2 to stimulation pattern changes were 0.47 ± 0.02 s, 0.53 s, and 0.48 s, respectively. Furthermore, for both TT1 and TT2, the absolute error of virtual ankle control reduced by about 50% with the addition of vibrotactile feedback. These results suggest that it is promising to apply the vibrotactile feedback system for the control of robotic transtibial prostheses.

Original languageEnglish
Article number00008
JournalFrontiers in Neurorobotics
Volume10
Issue numberAUG
DOIs
StatePublished - 2016
Externally publishedYes

Keywords

  • Human-centered closed-loop control
  • Position control
  • Robotic transtibial prostheses
  • Vibrotactile feedback
  • Vibrotactile stimulation
  • Volitional myoelectric control

Fingerprint

Dive into the research topics of 'Combining vibrotactile feedback with volitional myoelectric control for robotic transtibial prostheses'. Together they form a unique fingerprint.

Cite this