Abstract
Large-field-of-view stereo vision system lacks flexible and high-precision calibration methods. To this end, we proposed a new distance-related distortion model based calibration method combining 3D points and checkerboards. The experiment indicates that the proposed method has a root mean square of fewer than 0.08 pixels for the reprojection error on the calibration dataset, and the mean relative error of length measurement in a volume of 5.0 m × 2.0 m × 16.0 m is 3.6%0. Compared with other distance-related models, the proposed model has the lowest reprojection error on the test dataset. Besides, in contrast to other calibration methods, our method offers enhanced accuracy and greater flexibility.
| Original language | English |
|---|---|
| Pages (from-to) | 21816-21833 |
| Number of pages | 18 |
| Journal | Optics Express |
| Volume | 31 |
| Issue number | 13 |
| DOIs | |
| State | Published - 19 Jun 2023 |
Fingerprint
Dive into the research topics of 'Calibration method for large-field-of-view stereo vision system based on distance-related distortion model'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver