Skip to main navigation Skip to search Skip to main content

Biomechanical responses of human lumbar spine and pelvis according to the Roussouly classification

  • Wei Wang
  • , Baoqing Pei*
  • , Shuqin Wu*
  • , Da Lu
  • , Peiyan He
  • , Chenghao Ma
  • , Xueqing Wu
  • *Corresponding author for this work
  • Beihang University
  • Shanxi Polytechnic Institute

Research output: Contribution to journalArticlepeer-review

Abstract

Background Few studies have analyzed the different biomechanical properties of the lumbar with various morphological parameters, which play an important role in injury and degeneration. This study aims to preliminarily investigate biomechanical characteristics of the spine with different sagittal alignment morphotypes by using finite element (FE) simulation and in-vitro testing. Methods According to the lumbar-pelvic radiographic parameters of the Chinese population, the parametric FE models (L1-S1-pelvis) of Roussouly’s type (1–4) were validated and developed based on the in-vitro biomechanical testing. A pure moment of 7.5 Nm was applied in the three anatomical planes to simulate the physiological activities of flexion, extension, left-right lateral bending and left-right axial rotation. Results The sagittal configuration of four Roussouly’s type models had a strong effect on the biomechanical responses in flexion and extension. The apex of the lumbar lordosis is a critical position where the segment has the lowest range of motion among all the models. In flexion-extension, type 3 and 4 models with a good lordosis shape had a more uniform rotation distribution at each motor function segment, however, type 1 and 2 models with a straighter spine had a larger proportion of rotation at the L5-S1 level. In addition, type 1 and 2 models had higher intradiscal pressures (IDPs) at the L4-5 segment in flexion, while type 4 model had larger matrix and fiber stresses at the L5-S1 segment in extension. Conclusion The well-marched lordotic type 3 lumbar had greater stability, however, a straighter spine (type 1 and 2) had poor balance and load-bearing capacity. The hypolordotic type 4 model showed larger annulus fiber stress. Therefore, the sagittal alignment of Roussouly’s type models had different kinetic and biomechanical responses under various loading conditions, leading to different clinical manifestations of the lumbar disease.

Original languageEnglish
Article numbere0266954
JournalPLOS ONE
Volume17
Issue number7 July
DOIs
StatePublished - Jul 2022

Fingerprint

Dive into the research topics of 'Biomechanical responses of human lumbar spine and pelvis according to the Roussouly classification'. Together they form a unique fingerprint.

Cite this