Abstract
As a core unit of HTGRs (high-temperature gas-cooled reactors), the quality of spherical fuel elements is directly related to the safety and reliability of HTGRs. In line with the design and performance requirements of the spherical fuel elements, no coated fuel particles are permitted to enter the fuel-free zone of a spherical fuel element. For fast and accurate detection of escaped coated fuel particles, X-ray DR (digital radiography) imaging with a step-by-step circular scanning trajectory was adopted for Chinese 10MW HTGRs. The scanning parameters dominating the volume of the blind zones were optimized to ensure the missing detection of the escaped coated fuel particles is as low as possible. We proposed a dynamic calibration method for tracking the projection of the fuel-free zone accurately, instead of using a fuel-free zone mask of fixed size and position. After the projection data in the fuel-free zone were extracted, image and graphic processing methods were combined for automatic recognition of escaped coated fuel particles, and some practical inspection results were presented.
| Original language | English |
|---|---|
| Pages (from-to) | 385-398 |
| Number of pages | 14 |
| Journal | Energy |
| Volume | 68 |
| DOIs | |
| State | Published - 15 Apr 2014 |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 7 Affordable and Clean Energy
Keywords
- Automatic recognition
- Digital radiography
- High-temperature gas-cooled reactors
- Spherical fuel elements
Fingerprint
Dive into the research topics of 'Automatic X-ray inspection for escaped coated particles in spherical fuel elements of high temperature gas-cooled reactor'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver