Skip to main navigation Skip to search Skip to main content

Applications of Near-Infrared Fluorescence Imaging and Angiography of Inferior Vesical Artery in Laparoscopic Lateral Lymph Node Dissection: A Prospective Nonrandomized Controlled Study

  • Bin Tang
  • , Sicheng Zhou
  • , Kunshan He
  • , Shiwen Mei
  • , Wenlong Qiu
  • , Xu Guan
  • , Fucheng Liu
  • , Chongwei Chi
  • , Xishan Wang
  • , Jie Tian*
  • , Qian Liu
  • , Jianqiang Tang*
  • *Corresponding author for this work
  • Chinese Academy of Medical Sciences
  • Peking University
  • Beihang University
  • Beijing Fengtai Hospital
  • CAS - Institute of Automation

Research output: Contribution to journalArticlepeer-review

Abstract

BACKGROUND: Near-infrared imaging with indocyanine green has been used to guide lateral lymph node dissection, yet its efficacy and benefits need further investigation. OBJECTIVE: To investigate the efficacy and feasibility of near-infrared fluorescence imaging and angiography of the inferior vesical artery in laparoscopic lateral lymph node dissection. DESIGN: A prospective nonrandomized controlled study. SETTINGS: Single-center study. PATIENTS: Patients with lower rectal cancer who underwent total mesorectal excision plus lateral lymph node dissection. MAIN OUTCOME MEASURES: A cohort of 108 patients was enrolled. After propensity score matching, 29 patients in the near-infrared group and 50 patients in the non-near-infrared group were matched. The total number of harvested lateral lymph nodes, positive lateral lymph nodes, inferior vesical artery preservation, and postoperative urinary function were compared. RESULTS: After propensity score matching, both groups had similar baseline characteristics. The total number of harvested lateral lymph nodes in the near-infrared group was significantly higher (12 vs 9, p = 0.013), but positive lateral lymph nodes were similar between the 2 groups (1 vs 1, p = 0.439). The inferior vesical artery preservation ratio was significantly increased with the aid of indocyanine green angiography (93.1% vs 56.0%, p < 0.001). The non-near-infrared group required more days for urinary catheter removal than the near-infrared group (5 vs 4, p = 0.046). Urinary recatheterization tended to occur more frequently in the non-near-infrared group, with a marginally significant trend (16% vs 0%, p = 0.059). The non-near-infrared group tended to have more cases with residual urine volume ≥50 mL than the near-infrared group (20.0% vs 3.4%, p = 0.087), especially in the bilateral dissection subgroup (41.2% vs 0%, p = 0.041). LIMITATIONS: Small sample size. CONCLUSIONS: Near-infrared imaging increased the number of harvested lateral lymph nodes, whereas real-time indocyanine green fluorescence angiography ensured the preservation of the inferior vesical artery and tended to improve postoperative urinary function.

Original languageEnglish
Pages (from-to)175-184
Number of pages10
JournalDiseases of the Colon and Rectum
Volume67
Issue number1
DOIs
StatePublished - 1 Jan 2024

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Indocyanine green
  • Inferior vesical artery
  • Lateral lymph node dissection
  • Near-infrared imaging
  • Rectal cancer
  • Urinary function

Fingerprint

Dive into the research topics of 'Applications of Near-Infrared Fluorescence Imaging and Angiography of Inferior Vesical Artery in Laparoscopic Lateral Lymph Node Dissection: A Prospective Nonrandomized Controlled Study'. Together they form a unique fingerprint.

Cite this